| |
|
|
Recent Publications
Att W, Hori N, Takeuchi M, Ouyang J, Yang Y, Anpo M, Ogawa T. Time-dependent degradation of titanium osteoconductivity: an implication of biological aging of implant materials. Biomaterials. 2009 Oct;30(29):5352-63.
Abstract
The shelf life of implantable materials has rarely been addressed. We determined whether osteoconductivity of titanium is stable over time. Rat bone marrow-derived osteoblasts were cultured on new titanium disks (immediately after acid-etching), 3-day-old (stored after acid-etching for 3 days in dark ambient conditions), 2-week-old, and 4-week-old disks. Protein adsorption capacity, and osteoblast migration, attachment, spread, proliferation and mineralization decreased substantially on old titanium surfaces in an age-dependent manner. When the 4-week-old implants were placed into rat femurs, the biomechanical strength of bone-titanium integration was less than half that for newly processed implants at the early healing stage. More than 90% of the new implant surface was covered by newly generated bone compared to 58% for 4-week-old implants. This time-dependent biological degradation was also found for machined and sandblasted titanium surfaces and was associated with progressive accumulation of hydrocarbon on titanium surfaces. The new surface could attract osteoblasts even under a protein-free condition, but its high bioactivity was abrogated by masking the surface with anions. These results uncover an aging-like time-dependent biological degradation of titanium surfaces from bioactive to bioinert. We also suggest possible underlying mechanisms for this biological degradation that provide new insights into how we could inadvertently lose, and conversely, maximize the osteoconductivity of titanium-based implant materials.
http://www.ncbi.nlm.nih.gov/pubmed/19595450?dopt=Citation
First authors comment:
The discovery of this phenomenon has changed the definition of titanium as a bioinert material. Titanium is no more bioinert but bioactive if it is new. I am so honored and proud to be in the transformation of titanium science.
Tsukimura N, Yamada M, Aita H, Hori N, Yoshino F, Chang-Il Lee M, Kimoto K, Jewett A, Ogawa T. N-acetyl cysteine (NAC)-mediated detoxification and functionalization of poly(methyl methacrylate) bone cement. Biomaterials. 2009 Jul;30(20):3378-89. Epub 2009 Mar 20.
Abstract
Currently used poly(methyl methacrylate) (PMMA)-based bone cement lacks osteoconductivity and induces osteolysis and implant loosening due to its cellular and tissue-toxicity. A high percentage of revision surgery following the use of bone cement has become a significant universal problem. This study determined whether incorporation of the amino acid derivative N-acetyl cysteine (NAC) in bone cement reduces its cytotoxicity and adds osteoconductivity to the material. Biocompatibility and bioactivity of PMMA-based bone cement with or without 25mm NAC incorporation was examined using rat bone marrow-derived osteoblastic cells. Osteoconductive potential of NAC-incorporated bone cement was determined by microCT bone morphometry and implant biomechanical test in the rat model. Generation of free radicals within the polymerizing bone cement was examined using electron spin resonance spectroscopy. Severely compromised viability and completely suppressed phenotypes of osteoblasts on untreated bone cement were restored to the normal level by NAC incorporation. Bone volume formed around 25mm NAC-incorporated bone cement was threefold greater than that around control bone cement. The strength of bone-bone cement integration was 2.2 times greater for NAC-incorporated bone cement. For NAC-incorporated bone cement, the spike of free radical generation ended within 12h, whereas for control bone cement, a peak level lasted for 6 days and a level greater than half the level of the peak was sustained for 20 days. NAC also increased the level of antioxidant glutathione in osteoblasts. These results suggest that incorporation of NAC in PMMA bone cement detoxifies the material by immediate and effective in situ scavenging of free radicals and increasing intracellular antioxidant reserves, and consequently adds osteoconductivity to the material.
http://www.ncbi.nlm.nih.gov/pubmed/19303139?dopt=Citation
First authors comment:
24/7 work never let you down. It has been a great honor to work on this project, which I believe will change the history of orthopedic reconstruction.
Aita H, Hori N, Takeuchi M, Suzuki T, Yamada M, Anpo M, Ogawa T. The effect of ultraviolet functionalization of titanium on integration with bone. Biomaterials. 2009 Feb;30(6):1015-25. Epub 2008 Nov 29.
Abstract
Titanium implants are used as a reconstructive anchor in orthopedic and dental diseases and problems. Recently, ultraviolet (UV) light-induced photocatalytic activity of titanium has earned considerable and broad interest in environmental and clean-energy sciences. This study determines whether UV treatment of titanium enhances its osteoconductive capacity. Machined and acid-etched titanium samples were treated with UV for various time periods up to 48h. For both surfaces, UV treatment increased the rates of attachment, spread, proliferation and differentiation of rat bone marrow-derived osteoblasts, as well as the capacity of protein adsorption, by up to threefold. In vivo histomorphometry in the rat model revealed that new bone formation occurred extensively on UV-treated implants with virtually no intervention by soft tissue, maximizing bone-implant contact up to nearly 100% at week 4 of healing. An implant biomechanical test revealed that UV treatment accelerated the establishment of implant fixation 4 times. The rates of protein adsorption and cell attachment strongly correlated with the UV dose-responsive atomic percentage of carbon on TiO2, but not with the hydrophilic status. The data indicated that UV light pretreatment of titanium substantially enhances its osteoconductive capacity, in association with UV-catalytic progressive removal of hydrocarbons from the TiO2 surface, suggesting a photofunctionalization of titanium enabling more rapid and complete establishment of bone-titanium integration.
http://www.ncbi.nlm.nih.gov/pubmed/19042016?dopt=Citation
First authors comment:
I enjoyed the moment when an idea and revelation come up suddenly and accidentally. Interestingly, these moments comes at night and filled with confidence and hope somehow. The discovery of this photofunctionalization of titanium will revolutionize the implant therapy.
Kelly J, Lin A, Wang CJ, Park S, Nishimura I. Vitamin D and bone physiology: demonstration of vitamin D deficiency in an implant osseointegration rat model. J Prosthodont. 2009 18(6):473-8. 2009
ABSTRACT
PURPOSE: The patient population varies in nutritional deficiencies, which may confound the host response to biomaterials. The objective of this study was to evaluate the effect of a common deficiency of vitamin D on implant osseointegration in the rat model. MATERIALS AND METHODS: Male Sprague-Dawley rats were maintained under the cessation of vitamin D intake and UV exposure. The serum levels of 1,25(OH)(2)D(3), 25 OHD(3), Ca, and P were determined. Miniature cylindrical Ti6Al4V implants (2-mm long, 1-mm diameter) were fabricated with double acid-etched (DAE) surface or modified DAE with discrete crystalline deposition (DCD) of hydroxyapatite nanoparticles. DAE and DCD implants were placed in the femurs of vitamin D-insufficient and control rats. After 14 days of healing, the femur-implant samples were subjected to implant push-in test and nondecalcified histology. The surfaces of recovered implant specimens after the push-in test were further evaluated by scanning electron microscopy (SEM). RESULTS: The decreased serum level of 25 OHD(3) demonstrated the establishment of vitamin D insufficiency in this model. The implant push-in test revealed that DAE and DCD implants in the vitamin D-insufficient group (15.94 +/- 8.20 N, n = 7; 15.63 +/- 3.96 N, n = 7, respectively) were significantly lower than those of the control group (24.99 +/- 7.92 N, n = 7, p < 0.05; 37.48 +/- 17.58 N, n = 7, p < 0.01, respectively). The transcortical bone-to-implant contact ratio (BIC) was also significantly decreased in the vitamin D-insufficient group. SEM analyses further suggested that the calcified tissues remaining next to the implant surface after push-in test appeared unusually fragmented. CONCLUSIONS: The effect of vitamin D insufficiency significantly impairing the establishment of Ti6Al4V implant osseointegration in vivo was unexpectedly profound. The outcome of Ti-based endosseous implants may be confounded by the increasing prevalence of vitamin D insufficiency in our patient population.
Comment by the author (by Jim)
It was an honor for us to have the opportunity to research in the Weintraub Center at UCLA. The opportunity allowed us the chance to evaluate osseointegration in a Vitamin D deficient model which could have profound long-term effects on the treatment of patients.
|
|